Abstract

DESCRIPTION (provided by applicant): Here we propose the development of molecular diagnostics that can accurately and quantitatively measure multiple protein biomarkers at the point-of-care, within the 15-minute timeframe of a typical patient/provider interaction. Specifically, we propose major technological advancements in our E-AB sensing platform to achieve this goal. The E-AB sensor is based on the binding-induced folding of electrode- bound DNA aptamers. Significant preliminary data indicates that the E-AB platform is sensitive (nanomolar to tens of picomolar), rapid (seconds to minutes), and selective enough to employ directly in urine, serum and other complex, unprocessed clinical materials. E-AB sensors are likewise reagentless, reusable, low volume (sub-microliter) and fully electronic (electrochemical), and are thus likely adaptable to point-of-care applications. The key hypothesis underlying this proposal is that, with sufficiently improved sensitivity and detection confidence, we can adapt the E-AB sensor platform to provide therapeutically actionable diagnostic information from clinical samples. And while our long-term objective is the fabrication of E-AB sensors suitable for the detection of a wide range of diagnostic proteins, our initial efforts will focus on a specific, representative application for which comparison with standard clinical approaches is readily achieved: the measurement of urinary and serum chemokines diagnostic of episodes of acute renal allograft rejection. Toward this end, we propose here improvements in the sensitivity and sample-to-sample stability of the E-AB sensors such that they reach the detection limits and reproducibility required for routine clinical use. We will achieve these goals by 1) selection of higher affinity aptamers (via a novel, ultra-efficient microfluidic- SELEX technology), 2) significant improvements in E-AB gain (via optimization of probe density and geometry, redox and attachment chemistry, and other important fabrication variables), and 3) development of control sensing elements that will enable precise background subtraction and correction. We have assembled an innovative and collaborative team with significant expertise in high-throughput aptamer selection, electrochemical detection and clinical practice. We believe that the success of this project will have significant ramifications -it will represent a large step toward a simple, reagentless, low cost diagnostic platform that is broadly applicable to molecular diagnostics at the point of care.

View original record on NIH RePORTER →